Design and Operation of Cryogenic Distillation Research Column for Ultra-Low Background Experiments

ORAL

Abstract

Motivated by isotopically enriched germanium (76Ge and 73Ge) for monocrystalline crystal growth for neutrinoless double-beta decay and dark matter experiments, a cryogenic distillation research column was developed. Without market availability of distillation columns in the temperature range of interest with capabilities necessary for our purposes, we designed, fabricated, tested, refined and operated a two-meter research column for purifying and separating gases in the temperature range from 100-200K. Due to interest in defining stratification, purity and throughput optimization, capillary lines were integrated at four equidistant points along the length of the column such that real-time residual gas analysis could guide the investigation. Interior gas column temperatures were monitored and controlled within 0.1oK accuracy at the top and bottom. Pressures were monitored at the top of the column to four significant figures. Subsequent impurities were measured at partial pressures below 2E-8torr. We report the performance of the column in this paper.

Authors

  • Christopher Chiller

    University of South Dakota

  • Angela Alanson Chiller

    University of South Dakota

  • Benjamin Jasinski

    University of South Dakota

  • Nathan Snyder

    University of South Dakota

  • Dongming Mei

    University of South Dakota