Impacts of coronary artery eccentricity on macro-recirculation and pressure drops using computational fluid dynamics

ORAL

Abstract

Coronary artery disease remains a major cause of mortality in developed countries, and is most often due to a localized flow-limiting stenosis, or narrowing, of coronary arteries. Patients often undergo invasive procedures such as X-ray angiography and fractional flow reserve to diagnose flow-limiting lesions. Even though such diagnostic techniques are well-developed, the effects of diseased coronary segments on local flow are still poorly understood. Therefore, this study investigated the effect of irregular geometries of diseased coronary segments on the macro-recirculation and local pressure minimum regions. We employed an idealized coronary artery model with a diameter of stenosis of 75{\%}. By systematically adjusting the eccentricity and the asymmetry of the coronary stenosis, we uncovered an increase in macro-recirculation size. Most importantly, the presence of this macro-recirculation signifies a local pressure minimum (identified by $\lambda_{\mathrm{2}}$ vortex identification method). This local pressure minimum has a profound effect on the pressure drops in both longitudinal and planar directions, which has implications for diagnosis and treatment of coronary artery disease.

*Supported by Australian Research Council LP150100233 and National Computational Infrastructure m45

Authors

  • Eric Poon

    • Univ of Melbourne
    • University of Melbourne
  • Vikas Thondapu

    • Univ of Melbourne
  • Peter Barlis

    • Univ of Melbourne
  • Andrew Ooi