Simulation of Left Ventricular Hemodynamics from 4D-Flow MRI Data
ORAL
Abstract
We investigate the diastolic hemodynamics in a patient-specific left ventricle (LV) of a healthy subject using four dimensional flow magnetic resonance imaging (4D-Flow MRI) measurement and numerical simulation. From four dimensional Cardiac Magnetic Resonance (CMR) Imaging data, the kinematics of the endocardium is reconstructed. The endocardial kinematics and the time varying velocity distribution from 4D-Flow MRI at the mitral orifice are prescribed as boundary conditions for the numerical simulation. Both 4D-Flow MRI data and numerical results show the classical formation of the mitral vortex ring (MVR) during E-wave filling. The in-vivo data reveals that a large three-dimensional vortex structure forms near in the mid-level region of LV during diastasis (mid-level vortex). This mid-level vortex is formed simultaneously with the MVR and has not been reported in the literature. Our results suggest that numerical simulation can be used to provide useful hemodynamic data given the inputs from 4D-Flow MRI, which is now available in clinical practice.
*We acknowledge the support of computational time from the Institute for Advanced Computational Science (Stony Brook University) and Argonne Leadership Computing Facility, which is a DOE Office of Science User Facility
–
Presenters
-
Trung Bao Bao Le
- North Dakota State University