Development of an Active Plasma Control System for Pegasus
POSTER
Abstract
The Phase II Pegasus ST experiment includes fully programmable power supplies for all magnet coils. These will be integrated with a digital feedback plasma control system (PCS), based on the PCS in use on DIII-D, to provide active feedback control of the plasma evolution. The initial goal is to control I$_{p}$(t), R(t), and Z(t). The feedback cycle consists of: 1) sampling magnetic diagnostics, 2) applying a response matrix derived from equilibrium reconstructions, 3) accounting for induced vessel currents and power supply frequency responses, and 4) adjusting the current demand, all on a timescale that is fast compared to the shot duration of $\sim $25 ms. Data is sampled via a 500 kHz, 96-channel CPCI digitizer from DTACQ Solutions, Ltd. The power supply control signals are generated by 16 analog waveform generators, with the option to utilize 32 digital I/O lines in the future. The PCS digitizer is controlled via a system of Linux-based computers that perform requisite computation-intensive tasks and interface to the existing LabVIEW control codes via a TCP/IP network link.
*Work supported by U.S. D.O.E. Grant DE-FG02-96ER54375.