Development of Absolute Calibration of the Phase Contrast Imaging Diagnostic and Experimental Tests in Alcator C-Mod

POSTER

Abstract

The Phase Contrast Imaging (PCI) system in Alcator C-Mod is used to measure density perturbations from MHD modes, turbulence and RF waves. Recently, an absolutely calibrated system has been installed. This system consists of a set of transducers which cover frequency from 30 kHz to 200 kHz, and wavenumber from 5.5 cm$^{-1}$ to 36.6 cm$^{-1}$. The amplitude and phase of the transducer wavefronts are measured using a calibrated microphone. We will present the system design and modeling of this calibration system. Initial results, including a comparison with experimental measurements will also be discussed, if available.

*Work supported by U. S. DOE under DE-FG02-94-ER54235 and DE-FC02-99-ER54512