RMP ELM Suppression with a Single Row of Coils in DIII-D
POSTER
Abstract
ELM suppression with $n=3$ resonant magnetic perturbations (RMPs) has been obtained in DIII-D with a single row of coils, at one poloidal angle, but was investigated using only the same dominant window in $q_{95}$ as used for the standard two row suppression [1]. However, the single row imposes a richer density of spectral components as compared with the double row. Further experiments have been done with the single row to compare the efficacy of ELM suppression and the location and width of resonant windows in $q_{95}$ for suppression. We present calculations of the single row vacuum field resonances in $q_{95}$ and compare with experimental results. \vskip6pt \noindent [1] M.E. Fenstermacher et al., Nucl. Fusion {\bf 48}, 122001 (2008).
*Work supported in part by US DOE under DE-FC02-04ER54698, DE-AC52-07NA27344, DE-FG02-05ER54809 and DE-AC02-09CH11466.