Comparison of Deuterium-Deuterium-Deuterium and Neon-Deuterium-Deuterium Triple Shell Gas-Puff Z-pinch on the Level of 3 MA

POSTER

Abstract

The experiments of a triple shell gas-puff Z-pinch were carried out on the GIT-12 generator at IHCE in Tomsk during the April-May-June campaign in 2012. We diagnosed 17 Z-pinch shots where the triple D$_2$-D$_2$-D$_2$ (with the linear mass in the range of 50 - 255 $\mu$g/cm) and Ne-D$_2$-D$_2$ (with the linear mass in the range of 110 - 285 $\mu$g/cm) gas-puffs with diameter of 160 mm / 80 mm / 30 mm were mostly used as loads. This contribution is focused on the comparison of the results obtained by X-ray and neutron diagnostics, especially to the difference in reconstructed neutron energy spectra and obtained neutron yields (with the maximum of $3.3 \times 10^{11}$ neutrons/shot on a current level of 2.5 MA). The time correlations with other diagnostics such as electrical characteristics, a visible streak camera and MCP frames are also presented.

*Work supported by MEYS research programs No. ME09087, No. LA08024, by GACR grant No. P205/12/0454 and grant CRA IAEA No. 14817.

Authors

  • K. Rezac

    • FEE CTU in Prague
  • Daniel Klir

    • FEE CTU in Prague
  • P. Kubes

    • FEE CTU in Prague
  • J. Kravarik

    • FEE CTU in Prague
  • A. Shishlov

    • IHCE Tomsk
  • A. Labetsky

    • IHCE Tomsk
  • N. Ratakhin

    • IHCE Tomsk