Correcting for Background Emission Effects in \mbox{DIII-D} LIBEAM Measurements
POSTER
Abstract
A novel background correction technique has been developed for the DIII-D neutral lithium beam diagnostic (LIBEAM) which is used for diagnosing the local density profile $n_e(r)$ and current density $j(r)$ in the edge ($\rho \ga 0.8$) region of the plasma. The diagnostic relies on the Zeeman splitting of the collisionally excited lithium 2S-2P line in the tokamak magnetic field. Combined spectroscopy and polarimetry are then used to determine the magnetic field components and thence $j(r)$. Background plasma light due to imperfect spectral filtering can represent a significant systematic error in these measurements in some cases. To correct for this effect, a beam splitter was used in conjunction with 670.3$\,$nm and 649.9$\,$nm filters. The output signals from these two filters were then used to determine the non-beam background in real time at the observation point and account for it in the analysis. This process of correcting for background noise allows a more accurate determination of the pitch angle of the plasma under high-density conditions.
*Work supported in part by the the National Undergraduate Fellowship Program in Plasma Physics and Fusion Energy Sciences and the US DOE under DE-FC02-04ER54698, DE-AC05-06OR23100, and SC-G903402.