Modeling Detached Divertor Plasma Characteristics in the DIII-D Tokamak

ORAL

Abstract

Detached divertor-plasma operation, where a large fraction of the core exhaust power is radiated before striking the target plates, is attractive for limiting the peak target heat flux. Such plasmas have electron temperature $\sim$ 1 eV near the target. Changing the position of the separatrix strike points on the geometrically varied DIII-D target plates is allowing a systematic study of how plate shape impacts accessibility to detached operation. Reported here are 2D plasma/neutral transport simulations of these configurations using the UEDGE code including cross-field drifts and impurities. Results are given on how the onset of detachment scales with strike-point location, wall pumping of neutrals, separatrix density, and core power. Different initial conditions sometimes yield different steady-state solutions for identical input parameters, one being an attached plasma and the other detached. Comparisons are made of simulation results and experimental measurements, especially divertor Thomson scattering data.

*Work supported by US DOE, DE-AC52-07NA27344, DE-FC02-04ER54698, DE-FG02-07ER54917

Authors

  • T.D. Rognlien

    • Lawrence Livermore National Laboratory
    • LLNL
  • I. Joseph

    • Lawrence Livermore National Laboratory
    • LLNL
  • A.G. McLean

    • LLNL
    • Lawrence Livermore National Laboratory
  • G.D. Porter

    • LLNL
  • M.E. Rensink

    • LLNL
  • M. Umansky

    • LLNL
  • M. Groth

    • Aalto Univ.
    • Aalto U.
  • A.Y. Pigarov

    • UCSD