Main Ion Isotope dependence of impurity transport in ion and electron-heating dominated H-mode plasmas in the DIII-D tokamak
ORAL
Abstract
The impurity confinement time τimp is up to 3x shorter in hydrogen (H) plasmas than in dimensionally similar deuterium (D) plasmas. The transport of calcium is investigated with the laser blow-off system in ELM-y H-mode discharges. Adding ECH to NBI heated D discharge reduces τimp 3x while τimp remains unaffected by ECH in H plasmas. The lack of τimp variation in H is a consequence of the 10x faster impurity diffusion compared to an NBI-heated D reference, which only slightly increases with ECH. The normalized impurity density gradient R/Ln is nearly identical for the H and D plasmas, rising from -2 in NBI heated plasmas to 2 in NBI+ECH heated plasmas. Turbulent transport is modeled by the quasilinear CGYRO model, which correctly reproduces the increase in impurity diffusion caused by a change of heating mix. However, the diffusion in H compared to the D case increases only by a factor 2-3, while in the experiment by a factor of 10. A sensitivity scan by CGYRO indicates impurity transport is mainly affected by indirect effects associated with the isotope change, such as profile gradients, electron-ion heat exchange, and beta stabilization but negligible direct effects of isotope.
*Work supported by the US DOE under DE-FC02-04ER54698,DE-SC0014264,DE-FG02-08ER54999,DE-FG02-07ER54917.
–