Understanding electrode plasma formation on wires and thin foils via vacuum ultraviolet spectroscopy of desorbed surface contaminants
ORAL
Abstract
Power flow studies on the 30-MA, 100-ns Z facility at Sandia National Labs have shown that plasma in the facility’s magnetically insulated transmission lines can result in a loss of current delivered to the load.1 During the current pulse, thermal energy deposition into the electrodes causes neutral surface contaminant layers to desorb, ionize, and form plasma in the anode-cathode gap.2,3 We suspect that as the electrode thickness decreases relative to the skin depth of the current pulse (50−100 µm for aluminum and 100-500 µm for stainless steel, for a 100−500-ns pulse), the thermal energy delivered to the surface contaminant layers increases, and thus, faster desorption rates.
We review experimental results on a smaller scaled facility (≤ 1 MA) to characterize the contaminants using the plasma temperature, density, and determination of the species and their ionized states during surface desorption. These results are collected from a vacuum ultraviolet spectrometer developed to measure the spectra from wires and foils of varying thicknesses (5 µm – 1 mm) and materials (aluminum and stainless steel). To quickly compare theoretical values to experimental results, a newly developed, semi-analytic desorption and heating model is then used.
1. W.A. Stygar et al., Phys. Rev. S.T.-A.B. 12, 120401 (2009)
2. M.R. Gomez et al., Phys. Rev. A.B. 20, 010401 (2017)
3. T.J. Smith et al., Rev. Sci. Inst. 92, 053550 (2021)
We review experimental results on a smaller scaled facility (≤ 1 MA) to characterize the contaminants using the plasma temperature, density, and determination of the species and their ionized states during surface desorption. These results are collected from a vacuum ultraviolet spectrometer developed to measure the spectra from wires and foils of varying thicknesses (5 µm – 1 mm) and materials (aluminum and stainless steel). To quickly compare theoretical values to experimental results, a newly developed, semi-analytic desorption and heating model is then used.
1. W.A. Stygar et al., Phys. Rev. S.T.-A.B. 12, 120401 (2009)
2. M.R. Gomez et al., Phys. Rev. A.B. 20, 010401 (2017)
3. T.J. Smith et al., Rev. Sci. Inst. 92, 053550 (2021)
*This work was supported by Sandia National Labs through the ASAP Mission Campaign as well as the LDRD Program, Project No. 222323. Sandia is a multi-mission lab managed and operated by National Technology and Engineering Solutions of Sandia, LLC., a wholly owned subsidiary of Honeywell International, Inc., for the US DOE's NNSA under contract DE-NA-0003525. This paper describes objective technical results and analysis. Any subjective views or opinions that might be expressed in the paper do not necessarily represent the views of the US DOE or the US Government.
–
Presenters
-
Trevor J Smith
- University of Michigan