Electrostatic patch potentials in Casimir force measurements
ORAL
Abstract
Measurements of the Casimir force require the elimination of the electrostatic force between interacting surfaces. The force can be minimized by applying a potential to one of the two surfaces. However, electrostatic patch potentials remain and contribute an additional force which can obscure the Casimir force signal [1-2]. We will discuss recent measurements of patch potentials made with Heterodyne Amplitude-Modulated Kelvin Probe Force Microscopy that suggest patches could be responsible for \textgreater 1{\%} of the signal in some Casimir force measurements, and thus make the distinction between different theoretical models of the Casimir force (e.g. a Drude-model or a plasma-model for the dielectric response) difficult to discern [3].\\[4pt] [1] C. C. Speake and C. Trenkel, Phys. Rev. Lett. 90, 160403 (2003).\\[0pt] [2] R. O. Behunin, F. Intravaia, D. A. R. Dalvit, P. A. Maia Neto, and S. Reynaud, Phys. Rev. A 85, 012504 (2012).\\[0pt] [3] J. L. Garrett, D. Somers, and J. N. Munday, J. Phys. Condens. Matter (in press) arXiv:1409.5012 (2014).
–
Authors
-
Joseph Garrett
University of Maryland, Physics, Univ. of Maryland
-
David Somers
University of Maryland, College Park, University of Maryland
-
Jeremy Munday
University of Maryland