Proposal for a More Efficient Acoustic Array Design to Calculate Flow Rate Through a Cylindrical Conduit

POSTER

Abstract

A new design is proposed for the existing acoustic array, a device used to measure the flow rate through a cylindrical conduit via a series of transducers. The original acoustic array consists of a 2.000 inch diameter steel pipe with 128 transducers located along the top, spaced 2.000 inches apart along the length of the pipe. The total length of the original acoustic array in this configuration is over 21 feet long (254 inches). The analog acoustic information obtained from the array is sent through an amplifier, an analog digital converter, and then to a computer to be analyzed in order to determine rate of flow. The new design proposes a 3.000 inch diameter steel pipe with 128 transducers located along the equatorial axis of the pipe, spaced 0.287 inches apart. This new design leads to a more manageable apparatus, as the pipe length needed will be decreased from over 21 feet to less than 3.5 feet in length.

Authors

  • Kathryn Ham

    Georgia College \& State Univ

  • Quintorious Bivins

    Georgia College \& State Univ

  • Arthur Shue

    Georgia College \& State Univ