Microwave Initiated Atomic Spectra from Select Atomic Species
ORAL
Abstract
Quantum states were energized in gaseous Helium ($^{3}$He and $^{4}$He) using a 2.45 GHz magnetron coupled to the gases. A residual gas analyzer was used to determine the mass of each species. An Ocean Optics Optical Spectrometer collected the light via an optic probe. The data show unique spectral emission line shapes. Data using both computational as well as theoretical techniques are presented. Traditional high voltage arc discharge data were taken for the gas species to compare with microwave stimulated atomic emissions.
–
Authors
-
James Roberts
University of North Texas
-
Jai Dahiya
Southeast Missouri State University
-
Aman Anand
University of North Texas
-
Rick Croley
University of North Texas Office of Economic Development and Technology Transfer, University of North Texas